Special Conditions: Epoxy-Coated, Stainless, and Post-Tensioning Special reinforcement types introduce particular placing requirements. Epoxy-coated bars need gentle handling to avoid coating damage and may require increased embedment lengths. Stainless steel reinforcement and galvanized supports have specific connections and compatibility needs. In post-tensioned construction, placement of ducts, sheathings, and temporary supports for tendons must be coordinated carefully with rebar placement.
Common Problems and Remedies Typical issues include inadequate cover due to crushed or displaced chairs, congested reinforcement hindering concrete consolidation, mislocated bars from poor layout, and damaged bar coatings. Remedies involve using larger or more frequent supports, prefabricating cages, revising bar layouts in collaboration with designers, and instituting stricter inspection controls. Crsi Placing Reinforcing Bars.pdf
Safety and Handling Handling heavy reinforcement involves ergonomic and safety concerns. CRSI highlights safe lifting, use of mechanical aids, avoidance of sharp ends, and protection of workers from trips and impalement. Bar ends should be capped or bent where necessary. Stable storage and staging areas prevent distortion and facilitate correct placement. use of mechanical aids